Inquiry
Form loading...
China Suppliers for 6-220kV High Voltage Reactors - Quality Inductors from Leading Factory
Hot Products

China Suppliers for 6-220kV High Voltage Reactors - Quality Inductors from Leading Factory

Reactors

Discover high-quality reactors, also referred to as inductors, from leading suppliers in China. These essential components are widely utilized in various circuits due to their ability to induce electromagnetic effects. With a degree of inductance, reactors effectively stabilize current changes, making them a vital choice for electronic applications. Trust our factory to provide reliable and efficient reactors that meet industry standards and support your circuit designs.

    Reactors

    Reactors, also known as inductors, are widely used in circuits. Due to the electromagnetic induction effect, there is a certain degree of inductance in the circuit, which can prevent current changes. When a conductor is energized, a magnetic field is generated within a certain range of space it occupies, so all current carrying electrical conductors have a general sense of inductance. However, the inductance of a long and straight conductor is relatively small, and the magnetic field generated is not strong. Therefore, the actual reactor is a wire wound in the form of a solenoid, called a hollow reactor;

    Sometimes, in order to increase the inductance of this solenoid, an iron core is inserted into the solenoid, which is called an iron core reactor. Reactance is divided into inductive reactance and capacitive reactance. A more scientific classification is that inductive reactance (inductor) and capacitive reactance (capacitor) are collectively referred to as reactors. However, due to the existence of inductors in the past, which were called reactors, capacitors are now referred to as capacitive reactances, and reactors specifically refer to inductors.
    656ed8cij6

    The commonly used reactors in power systems include series reactors and parallel reactors. Series reactors are mainly used to limit short-circuit currents, and can also be connected in series or parallel with capacitors in filters to limit high-order harmonics in the power grid. Reactors in 220kV, 110kV, 35kV, and 10kV power grids are used to absorb capacitive reactive power from cable lines during charging. The operating voltage can be adjusted by adjusting the number of parallel reactors. Ultra high voltage parallel reactors have various functions to improve the operating conditions related to reactive power in power systems, mainly including:

    • 1

      The capacitance effect on lightly unloaded or lightly loaded lines to reduce transient overvoltage at power frequency;

    • 2

      Improve voltage distribution on long-distance transmission lines;

    • 3

      To balance the reactive power in the line as much as possible on site during light loads, preventing unreasonable flow of reactive power and reducing power loss on the line;

    • 4

      Reduce the steady-state voltage of the power frequency on the high-voltage bus when the large unit is parallel to the system, making it easier for the generator to be synchronized and parallel;

    • 5

      Prevent self excitation resonance phenomenon that may occur in generators with long lines;

    • 6

      When using a reactor neutral point through a small reactance grounding device, a small reactor can also be used to compensate for the phase to phase and phase to ground capacitance of the line, in order to accelerate the automatic extinguishing of the latent current and facilitate its use.

    The wiring of reactors can be divided into two ways: series connection and parallel connection. Series reactors usually serve as current limiting devices, while parallel reactors are often used for reactive power compensation.

    657e6707im

    Frequently Asked Questions (FAQ)

    What is the difference between a hollow reactor and an iron core reactor?

    A hollow reactor is a wire wound in the form of a solenoid without an internal core. An iron core reactor has an iron core inserted into the solenoid to increase its overall inductance.

    How do series reactors function in a power system?

    Series reactors serve mainly as current limiting devices to limit short-circuit currents. They can also be connected with capacitors in filters to limit high-order harmonics in the power grid.

    Why are parallel reactors used in power grids?

    Parallel reactors are primarily used for reactive power compensation. They absorb capacitive reactive power from cable lines during charging, helping to adjust and stabilize the operating voltage.

    What are the benefits of ultra-high voltage parallel reactors?

    They reduce transient overvoltage under light loads, improve voltage distribution on long-distance transmission lines, reduce power loss, facilitate generator synchronization, and prevent generator self-excitation.

    How does a neutral point reactor help in power lines?

    By grounding the neutral point through a small reactance device, it compensates for phase-to-phase and phase-to-ground capacitance, which accelerates the automatic extinguishing of latent currents.

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.

    description2

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.