Transformer Bushing and Reactor Bushing are essential components in power transformers and reactors, designed to effectively conduct high, medium, and low voltage currents. These bushings not only serve as current-carrying conductors but also function as insulating and sealing sleeves for the outer shell of transformer oil tanks. As a leading factory in China, we specialize in manufacturing high-quality transformer bushings that meet international standards. Our reliable products have made us one of the preferred suppliers in the industry, ensuring optimum performance and safety for your power systems.

    Our company apply international advanced professional electric field analysis software and high voltage bushing internal insulation optimization design software package to optimize the design of internal and external insulation of bushing, core calculation and field strength, and obtain the optimal design scheme to ensure Higher electrical performance.

    Our company adopt imported whole paper winder, using the whole paper winding process, seamless lap technology for paper and aluminum foil to achieve accurate electrode laser location and winding tension control, and ensure axial and radial field strength of condenser core uniform.

    Our company use imported mixing material pouring system and vacuum drying system to ensure resin effectively degassed and core fully dry. So obtain smaller dielectric dissipation and lower partial discharge of bushing core, which ensure product good electrical performance.

    Product Features & Structure
    • The main insulation of resin impregnated paper (RIP) bushing is condenser core combined by crepe paper and aluminum foil, which is cured after impregnated with resin epoxy.
    • External insulation is porcelain envelope or composite insulation.
    • Pollution class is anti-pollution class III, IV.
    • Test tap to measure capacitance, dielectric dissipation (tanδ) and partial discharge quantity is set on the middle grounding flange.
    • End shield to improve electric field distribution of bushing tail is equipped on the rail of bushing (on transformer side).
    • Good sealing and performance.
    • Oil-free, gas-free, explosion-proof, Green Environmental Protection.
    • Small size, light weight, high strength, any angle of mounting.
    • Easy transportation and mounting, maintenance-free.
    • Stable operation and high reliability.
    Operating Conditions
    Ambient Temperature:
    -45°C ~ +40°C
    Mounting Angle:
    Any angle of mounting
    Environmental Limits:
    Without chemical gas, extreme contamination and salt fog area
    Ordering & Customization Parameters
    • Product type (Product code)
    • Rated voltage and rated current
    • Creepage ratio distance (Creepage distance)
    • Specify dimension of CT grounding part
    • Design according to technical parameters of clients (attached various dimension of outline)
    • Customized design is also available upon requirements based on technical agreement with clients.
    Frequently Asked Questions (FAQ)
    What materials are used for the main insulation of the RIP bushing?
    The main insulation of the resin impregnated paper (RIP) bushing consists of a condenser core made from crepe paper and aluminum foil, which is cured after being thoroughly impregnated with epoxy resin.
    What environmental conditions are suitable for these bushings?
    The bushings are designed to operate in ambient temperatures ranging from -45°C to +40°C. They should be installed in areas free of chemical gas, extreme contamination, and salt fog.
    Can the bushings be mounted at specific angles?
    Yes, due to their small size, light weight, and high strength, these bushings can be installed at any mounting angle.
    Where is the test tap located and what is it used for?
    The test tap is set on the middle grounding flange. It is specifically designed to measure capacitance, dielectric dissipation (tanδ), and partial discharge quantity.
    Are customized designs available for specific client projects?
    Yes, customized design options are available. We can design according to the technical parameters and outline dimensions provided by clients, based on a mutual technical agreement.

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.

    description2

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.