Inquiry
Form loading...
10KV Epoxy Resin Dry-Type Transformer - Energy-Saving Solutions from China Suppliers & Factory
Hot Products

10KV Epoxy Resin Dry-Type Transformer - Energy-Saving Solutions from China Suppliers & Factory

Introducing the SC (B) 10 series 10KV epoxy resin dry-type transformer, a cutting-edge energy-saving solution proudly developed by leading China suppliers. This transformer is designed to meet modern energy efficiency standards while ensuring reliable performance and durability. Manufactured in our state-of-the-art factory, the SC (B) 10 series is ideal for various industrial applications, emphasizing both safety and sustainability. Upgrade your energy systems with our innovative transformers, ensuring your operations are efficient and environmentally friendly.

    The SC (B) series 6-35KV epoxy resin dry-type transformer is a new generation of energy-saving products. This series of distribution transformer products are used in special occasions where the transformer voltage is directly changed from 6-35KV power grid to 400V distribution, which can reduce the 6-35KV transmission and transformation links, and significantly reduce operation and maintenance costs. The 6-35KV level non excitation voltage regulating distribution transformer product has passed the appraisal and is established as a high-tech product.
    The product has the advantages of low loss, good flame retardancy, strong short-circuit resistance, small size, low noise, good lightning and electric shock resistance, and uniform temperature distribution. Moreover, due to the fact that epoxy resin dry-type transformers do not use transformer oil, they will not produce oil pollution and have no explosion risk. The product can be widely used as a distribution transformer for urban power system renovation, as well as for various occasions such as high-rise buildings, airports, stations, ports, subways, etc. that have strict and special requirements for fire protection and environmental protection.

    Product Structure

    The epoxy resin dry-type transformer mainly consists of transformer core, transformer winding, transformer insulation, transformer lead, transformer cooling device, and temperature measurement device. The coil of the distribution transformer is wound on a high-precision winding machine, and the low-voltage winding adopts a foil winding structure. The larger capacity transformer has a ventilation duct, and after winding, it is vacuum dried. The pouring and solidification process strictly follows the process requirements to ensure that there are no bubbles or cavities inside the coil, and the transformer product achieves high-quality operation.

    Core

    Selects high-quality and high magnetic grain oriented cold-rolled silicon steel sheets as the iron core, and adopts advanced silicon steel sheet cutting lines, 45 ° fully inclined seam stepped stacking sheets. The core column adopts advanced technologies such as F-grade weft free belt binding and iron yoke non punching pull plate fixation. The surface of the iron core is coated with epoxy resin to reduce the impact of magnetic leakage, effectively improve the magnetic circuit distribution, and reduce the noise, no-load loss, and no-load current.

    High Voltage Winding

    Adopts a segmented and layered structure, greatly reducing the interlayer voltage of the winding. It is formed by vacuum casting with epoxy resin filled with fillers, reducing local discharge inside the winding and improving the electrical performance of the coil. The interlayer is made of DMD epoxy resin pre impregnated fabric to increase the withstand voltage strength. The surface is filled with fiberglass mesh fabric to enhance the mechanical strength and short circuit resistance.

    Low Voltage Winding

    Adopts a foil structure, and the coil adopts an axial cooling air duct to enhance heat dissipation capacity. The interlayer of the low-voltage winding of the distribution transformer is made of DMD epoxy resin pre impregnated fabric, and the end is sealed with epoxy resin, forming an overall fixed connection.

    Product Features

    1. Flame Retardant

    Epoxy resin as an insulation material for SCB dry-type transformers is inherently flame retardant and will not support combustion in the event of a fire.

    2. Moisture Proof and Dust Resistant

    The surface of SCB dry-type transformer winding is sprayed with three proof paint, which will not affect the dry-type transformer in harsh environments such as dust and moisture.

    3. Sturdy Structure

    The winding of SCB dry-type transformer is cast and solidified with epoxy resin, with high mechanical strength and strong short-circuit resistance.

    4. Strong Overload Capacity

    SCB dry-type transformer has an insulation level of F, high heat resistance level, and improved operating capacity beyond the rated value of the brand.

    5. Convenient Maintenance

    SCB dry-type transformer does not require transformer oil, and can be dried by powering on after long-term shutdown.

    Usage Environment

    • Altitude: ≤ 1000 meters
    • Environmental Temperature Limits:
    Maximum Temperature
    +40 ℃
    Minimum Temperature
    -40 ℃
    Max Monthly Average
    +30 ℃
    Max Annual Average
    +20 ℃

    Frequently Asked Questions

    What are the primary applications of the SC (B) series dry-type transformer?

    It is widely used as a distribution transformer for urban power system renovation, as well as in locations with strict fire and environmental protection requirements, such as high-rise buildings, airports, stations, ports, and subways.

    Why is the SC (B) series transformer considered safe for fire-sensitive areas?

    The transformer uses epoxy resin as an insulating material, which is inherently flame retardant and will not support combustion. Additionally, because it does not use transformer oil, there is no risk of oil pollution or explosion.

    How does the core design reduce noise and energy loss?

    The core is constructed from high-quality, high magnetic grain-oriented cold-rolled silicon steel sheets with a 45° fully inclined seam stepped stacking design. The surface is coated with epoxy resin to reduce magnetic leakage, which effectively lowers noise, no-load loss, and no-load current.

    What makes the windings highly resistant to short circuits?

    The high-voltage winding is vacuum cast with filler-filled epoxy resin and reinforced with fiberglass mesh fabric. The low-voltage winding uses a foil structure sealed with epoxy resin. This solid casting method provides exceptional mechanical strength and short-circuit resistance.

    What are the environmental limits for installing this transformer?

    The transformer is designed for operation at altitudes of 1000 meters or less. The environmental temperatures must remain within a maximum of +40 ℃, minimum of -40 ℃, with a maximum monthly average of +30 ℃ and a maximum annual average of +20 ℃.

    Is maintenance difficult for the SCB dry-type transformer?

    No, maintenance is highly convenient. Since it does not use transformer oil, there is no need for oil checks or changes. If the transformer has been shut down for a long period, it can simply be dried by powering it on.

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.

    description2

    HEADING-TYPE-1

    High voltage parallel capacitors are suitable for parallel connection in AC power systems with power frequency (50Hz or 60Hz) of 1kV and above. They are used to compensate for inductive reactive power, improve power factor, improve voltage quality, reduce line losses, and fully utilize the efficiency of power generation and supply equipment.